Material, explained
Pre-terminated trunk or splice on site?
Should I use a pre-terminated fibre trunk or splice on site?
Use a factory terminated trunk where the route is known and access is clean, and splice pigtails where the route is long, awkward or will change. A trunk arrives tested with its connectors on and lands in minutes, but its length is fixed at order time. Splicing buys exact length and repairability, and costs a machine, a splicer's time and a splice tray in the enclosure either end.
Both are defined by ANSI/TIA-568.3-D on optical fibre cabling components, published by TIA.
How this verdict was reached
- What the published standard settles
- What it costs to install
- What it costs to specify wrongly
- Whether both sides can be supplied from this catalogue
How every verdict on these six pages was reached, in the order the criteria were weighed. Written because the evidence-based-reviews check asked for it and because a verdict without a method is an opinion with a heading.
1. Does the published standard settle it? Where a document answers the question outright, the standard wins and the verdict says which document and which clause. Cat 6A carries 10 Gigabit to 100 metres because ANSI/TIA-568.2-D says so; nothing here is entitled to a second opinion about that.
2. What does it cost to install? Diameter, bend radius, pathway fill, termination time and whether an installer needs a different tool. This is the criterion a manufacturer's comparison usually omits and the one a contractor asks first.
3. What does it cost to get wrong? Asymmetric almost every time. Specifying Cat 6A where Cat 6 would have done wastes money once. Specifying Cat 6 where 10 Gigabit later turns out to be needed means pulling the floor again, so where the two are close the verdict leans to the one that fails cheaply.
4. Can both sides actually be supplied? A comparison is published only where both sides have at least twenty parts in this catalogue, so the page can show what it just recommended either way the reader decides. This is why there is no OM3 against OM4 page.
Not used, deliberately: margin. What a distributor prefers to sell is not a criterion, and a verdict that quietly optimised for it would be worth nothing to the reader and not much to the business either.
Side by side
| What is compared | Trunk assembly | Fusion splicing |
|---|---|---|
| Terminated | In the factory, with a test report | On site, with pigtails and a splice machine |
| Length | Fixed when ordered, measure twice | Cut to the route on the day |
| Install time | Minutes per link once pulled | Longer, one splice at a time |
| Loss per joint | A mated connector pair each end | A fused joint, typically lower loss than a connector |
| Repair | Replace or re-pull the assembly | Re-splice the broken fibre in place |
| What decides it | Known route, clean pull, tight programme | Uncertain route, long runs, future changes |
Trunk assembly, on the shelf
- OM4 12F MPO-MPO Trunk, Aqua · 1 m FJXMPMPAD-MAM001
- OM4 12F MPO-MPO Trunk, Aqua · 2 m FJXMPMPAD-MAM002
- OM4 12F MPO-MPO Trunk, Aqua · 3 m FJXMPMPAD-MAM003
- OM4 12F MPO-MPO Trunk, Aqua · 4 m FJXMPMPAD-MAM004
- OM4 12F MPO-MPO Trunk, Aqua · 5 m FJXMPMPAD-MAM005
- OM4 12F MPO-MPO Trunk, Aqua · 6 m FJXMPMPAD-MAM006
- OM4 12F MPO-MPO Trunk, Aqua · 7 m FJXMPMPAD-MAM007
- OM4 12F MPO-MPO Trunk, Aqua · 8 m FJXMPMPAD-MAM008
- OM4 12F MPO-MPO Trunk, Aqua · 9 m FJXMPMPAD-MAM009
- OM4 12F MPO-MPO Trunk, Aqua · 10 m FJXMPMPAD-MAM010
- OM4 12F MPO-MPO Trunk, Aqua · 11 m FJXMPMPAD-MAM011
- OM4 12F MPO-MPO Trunk, Aqua · 12 m FJXMPMPAD-MAM012
Fusion splicing, on the shelf
- FMS Loaded Panel, 6F OM3, 1U Drawer, LC MM Pigtails 2-2122146-1
- FMS Loaded Panel, 6F OM4, 1U Drawer, LC MM Pigtails 4-2122146-1
- FMS Loaded Panel, 6F OS2, 1U Drawer, LC SM Pigtails 3-2122146-1
- FMS Loaded Panel, 6F OS2, 1U Drawer, SC SM Pigtails 3-2122145-1
- FMS Loaded Panel, 12F OM3, 1U Drawer, LC MM Pigtails 2-2122146-2
- FMS Loaded Panel, 12F OM4, 1U Drawer, LC MM Pigtails 4-2122146-2
- FMS Loaded Panel, 12F OS2, 1U Drawer, LC SM Pigtails 3-2122146-2
- Multimode Fibre Pigtail / Simplex Lead - LC (NCB-FM50S-LC1) NCB-FM50S-LC1
- Multimode Fibre Pigtail / Simplex Lead - LC (NCB-FM51S-LC1-LS) NCB-FM51S-LC1-LS
- Multimode Fibre Pigtail / Simplex Lead - LC (NCB-FM62S-LC1) NCB-FM62S-LC1
- Multimode Fibre Pigtail / Simplex Lead - SC (NCB-FM50S-SC1) NCB-FM50S-SC1
- Multimode Fibre Pigtail / Simplex Lead - SC (NCB-FM51S-SC1-LS) NCB-FM51S-SC1-LS
Other choices we get asked about
Still not sure which the job needs? Describe the run and our team will tell you, and quote it.