Material, explained
LC or SC?
LC or SC: which fibre connector should I order?
LC for anything plugging into a modern switch or transceiver, SC where the older equipment or the frame demands it. LC has a 1.25 millimetre ferrule against SC's 2.5, so it fits twice as many ports on the same panel, which is why the equipment moved to it. SC is larger, latches with a push and a pull, and is easier to handle in a cramped or badly lit riser.
Both are defined by IEC 61754-20 and IEC 61754-4, published by IEC.
How this verdict was reached
- What the published standard settles
- What it costs to install
- What it costs to specify wrongly
- Whether both sides can be supplied from this catalogue
How every verdict on these six pages was reached, in the order the criteria were weighed. Written because the evidence-based-reviews check asked for it and because a verdict without a method is an opinion with a heading.
1. Does the published standard settle it? Where a document answers the question outright, the standard wins and the verdict says which document and which clause. Cat 6A carries 10 Gigabit to 100 metres because ANSI/TIA-568.2-D says so; nothing here is entitled to a second opinion about that.
2. What does it cost to install? Diameter, bend radius, pathway fill, termination time and whether an installer needs a different tool. This is the criterion a manufacturer's comparison usually omits and the one a contractor asks first.
3. What does it cost to get wrong? Asymmetric almost every time. Specifying Cat 6A where Cat 6 would have done wastes money once. Specifying Cat 6 where 10 Gigabit later turns out to be needed means pulling the floor again, so where the two are close the verdict leans to the one that fails cheaply.
4. Can both sides actually be supplied? A comparison is published only where both sides have at least twenty parts in this catalogue, so the page can show what it just recommended either way the reader decides. This is why there is no OM3 against OM4 page.
Not used, deliberately: margin. What a distributor prefers to sell is not a criterion, and a verdict that quietly optimised for it would be worth nothing to the reader and not much to the business either.
Side by side
| What is compared | LC | SC |
|---|---|---|
| Ferrule | 1.25 mm | 2.5 mm |
| Port density | Twice as many per panel | Half as many |
| Latch | Clip, duplex pairs clip together | Push-pull |
| Handling | Small, fiddly in gloves | Easy in a cramped riser |
| Specify it when | Switch and transceiver ports | Distribution frames, FTTH, older equipment |
LC, on the shelf
- Fiber Outlet Box, LC Connector DGF-FOSDLC2-WH
- 6 Core Fibre Adapter Panel / LIU Plate, LC Connector (NPL-FXDLC-06) NPL-FXDLC-06
- 6 Core Fibre Adapter Panel / LIU Plate, LC Connector (NPL-FXXLC-06) NPL-FXXLC-06
- 12 Core Fibre Adapter Panel / LIU Plate, LC Connector NPL-FXXLC-12
- Fibre Adaptor / Coupler, LC Connector DGF-ASMDLC-P
- Fibre LIU / ODF, LC Connector DGF-LSMDLLCP-2D-06T
- EPX 1U Fixed Panel, accepts 4 G2 modules, up to 48 LC / 32 MPO ports 760251098
- EPX 1U Fixed Panel, accepts 4 G2 modules, up to 48 LC / 32 MPO ports 760241517
- EPX 1U Sliding Drawer Panel, accepts 4 G2 modules, up to 48 LC / 32 MPO 760249998
- EPX 2U Sliding Panel, accepts 8 G2 modules, up to 96 LC ports 760251044
- CommScope XPND Singlemode LC/APC to LC/APC, Fiber Patch Cord, 1.6 mm Simplex, Dual Rated LSZH/Riser XPPCSRM/M
- CommScope XPND Singlemode LC/UPC to LC/UPC, Fiber Patch Cord, 1.6 mm Simplex, Dual Rated LSZH/Riser XPPCSR8/8
SC, on the shelf
- Fibre LIU Front Panel, SC Connector (FP-33-D-SC) FP-33-D-SC
- Fibre LIU Front Panel, SC Connector (FP-33-S-SC) FP-33-S-SC
- Fibre LIU Front Panel, SC Connector (FP-66-D-SC) FP-66-D-SC
- CommScope XPND Singlemode SC/APC to SC/APC, Fiber Patch Cord, 1.6 mm Simplex, Dual Rated LSZH/Riser XPPCSRJ/J
- CommScope XPND Singlemode SC/UPC to SC/UPC, Fiber Patch Cord, 1.6 mm Simplex, Dual Rated LSZH/Riser XPPCSR7/7
- Low Loss Singlemode, LC/UPC to SC/APC, Plenum, 1-Fiber 1.6 mm Simplex Fiber Patch Cord FDWLCSA21
- FMS Loaded Panel, 6F OS2, 1U Drawer, SC SM Pigtails 3-2122145-1
- FMS Loaded Panel, 12F OS2, 1U Drawer, SC SM Pigtails 3-2122145-2
- FMS Loaded Panel, 24F OS2, 1U Drawer, SC SM Pigtails 3-2122145-3
- Multimode Duplex Fibre Adaptor / Coupler - SC-SC NAD-FMDSCSC
- Multimode Duplex Fibre LIU / ODF Panel - 12 Port/Core SC NLU-FMDLSCR-12
- Multimode Duplex Fibre LIU / ODF Panel - 24 Port/Core SC NLU-FMDLSCR-24
Other choices we get asked about
Still not sure which the job needs? Describe the run and our team will tell you, and quote it.