Material, explained
Stabiliser or UPS?
Servo stabiliser or UPS?
A UPS where the problem is outages, a stabiliser where the problem is voltage that wanders, and both where the supply does both, with the stabiliser in front. A servo stabiliser holds 180 to 260 volts at 230 continuously but has no battery. A UPS carries the load through a cut but corrects only within a narrower window and spends its battery on a bad supply. Most Indian sites with a generator want the pair.
How this verdict was reached
- What the published standard settles
- What it costs to install
- What it costs to specify wrongly
- Whether both sides can be supplied from this catalogue
How every verdict on these six pages was reached, in the order the criteria were weighed. Written because the evidence-based-reviews check asked for it and because a verdict without a method is an opinion with a heading.
1. Does the published standard settle it? Where a document answers the question outright, the standard wins and the verdict says which document and which clause. Cat 6A carries 10 Gigabit to 100 metres because ANSI/TIA-568.2-D says so; nothing here is entitled to a second opinion about that.
2. What does it cost to install? Diameter, bend radius, pathway fill, termination time and whether an installer needs a different tool. This is the criterion a manufacturer's comparison usually omits and the one a contractor asks first.
3. What does it cost to get wrong? Asymmetric almost every time. Specifying Cat 6A where Cat 6 would have done wastes money once. Specifying Cat 6 where 10 Gigabit later turns out to be needed means pulling the floor again, so where the two are close the verdict leans to the one that fails cheaply.
4. Can both sides actually be supplied? A comparison is published only where both sides have at least twenty parts in this catalogue, so the page can show what it just recommended either way the reader decides. This is why there is no OM3 against OM4 page.
Not used, deliberately: margin. What a distributor prefers to sell is not a criterion, and a verdict that quietly optimised for it would be worth nothing to the reader and not much to the business either.
Side by side
| What is compared | Servo stabiliser | Line interactive UPS |
|---|---|---|
| Corrects | Wide voltage swings, continuously | Modest sags and swells, in steps |
| On an outage | Stops with the supply | Carries the load on battery |
| Battery | None | Yes, and it wears |
| Suits | Sites on a poor supply, motors, air conditioning | Computers, network gear, recorders |
| Together | Stabiliser first, then the UPS | The UPS behind the stabiliser |
| What decides it | Whether the fault is voltage or absence | Log the supply for a week and see |
Servo stabiliser, on the shelf
- Numeric Voltsafe PLUS Single Phase Air Cooled 1 kVA Range 140V-280V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-1-KVA-RANGE-140V-280V
- Numeric Voltsafe PLUS Single Phase Air Cooled 1 kVA Range 170V-270V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-1-KVA-RANGE-170V-270V
- Numeric Voltsafe PLUS Single Phase Air Cooled 1-20 kVA Range NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-1-20-KVA-RANGE
- Numeric Voltsafe PLUS Single Phase Air Cooled 2 kVA Range 140V-280V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-2-KVA-RANGE-140V-280V
- Numeric Voltsafe PLUS Single Phase Air Cooled 2 kVA Range 170V-270V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-2-KVA-RANGE-170V-270V
- Numeric Voltsafe PLUS Single Phase Air Cooled 3 kVA Range 140V-280V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-3-KVA-RANGE-140V-280V
- Numeric Voltsafe PLUS Single Phase Air Cooled 3 kVA Range 170V-270V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-3-KVA-RANGE-170V-270V
- Numeric Voltsafe PLUS Single Phase Air Cooled 5 kVA Range 140V-280V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-5-KVA-RANGE-140V-280V
- Numeric Voltsafe PLUS Single Phase Air Cooled 5 kVA Range 170V-270V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-5-KVA-RANGE-170V-270V
- Numeric Voltsafe PLUS Single Phase Air Cooled 7.5 kVA Range 140V-280V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-7-5-KVA-RANGE-140V-280V
- Numeric Voltsafe PLUS Single Phase Air Cooled 7.5 kVA Range 170V-270V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-7-5-KVA-RANGE-170V-270V
- Numeric Voltsafe PLUS Single Phase Air Cooled 10 kVA Range 140V-280V NUM-VOLTSAFE-PLUS-SINGLE-PHASE-AIR-COOLED-10-KVA-RANGE-140V-280V
Line interactive UPS, on the shelf
- Numeric Battery Replacement Service NUM-BATTERY-REPLACEMENT-SERVICE
- Numeric Custom UPS Solution Planning NUM-CUSTOM-UPS-SOLUTION-PLANNING
- Numeric Digital 1000 HR V 1000 VA NUM-DIGITAL-1000-HR-V-1000-VA
- Numeric Digital 2000 HR V 2000 VA NUM-DIGITAL-2000-HR-V-2000-VA
- Numeric Digital 1000 HR-V IBB 1000 VA NUM-DIGITAL-1000-HR-V-IBB-1000-VA
- Numeric Digital 2000 HR-V IBB 2000 VA NUM-DIGITAL-2000-HR-V-IBB-2000-VA
- Numeric Digital 600 EX 600 VA NUM-DIGITAL-600-EX-600-VA
- Numeric Digital 1000 PLUS V 1000 VA NUM-DIGITAL-1000-PLUS-V-1000-VA
- Numeric Digital 2000 Plus 2000 VA NUM-DIGITAL-2000-PLUS-2000-VA
- Numeric HPi 33 EVO 10 kVA NUM-HPI-33-EVO-10-KVA
- Numeric HPi 33 EVO 10-40 kW Range NUM-HPI-33-EVO-10-40-KW-RANGE
- Numeric HPi 33 EVO 20 kVA NUM-HPI-33-EVO-20-KVA
Other choices we get asked about
Still not sure which the job needs? Describe the run and our team will tell you, and quote it.
Data Systems · +91 99595 55222 (call or WhatsApp) · 040-27811708 · admin@datasystems.co.in · Secunderabad (HQ) · Vijayawada · Visakhapatnam · Mon to Sat, 9:30 to 7
Some images on this site were created with AI and the item supplied may not look exactly as shown. The part code, not the picture, decides what ships.
Corrections and editorial policy · Privacy · Terms · Material, explained · Brands